Bug fixes for reported issues
This commit is contained in:
+30
-22
@@ -33,11 +33,14 @@ enum VictronDeviceType {
|
||||
DEVICE_TYPE_DCDC_CONVERTER = 0x04,
|
||||
DEVICE_TYPE_SMART_LITHIUM = 0x05,
|
||||
DEVICE_TYPE_INVERTER_RS = 0x06,
|
||||
DEVICE_TYPE_SMART_BATTERY_PROTECT = 0x07,
|
||||
DEVICE_TYPE_LYNX_SMART_BMS = 0x08,
|
||||
DEVICE_TYPE_MULTI_RS = 0x09,
|
||||
DEVICE_TYPE_VE_BUS = 0x0A,
|
||||
DEVICE_TYPE_DC_ENERGY_METER = 0x0B
|
||||
DEVICE_TYPE_GX_DEVICE = 0x07,
|
||||
DEVICE_TYPE_AC_CHARGER = 0x08,
|
||||
DEVICE_TYPE_SMART_BATTERY_PROTECT = 0x09,
|
||||
DEVICE_TYPE_LYNX_SMART_BMS = 0x0A,
|
||||
DEVICE_TYPE_MULTI_RS = 0x0B,
|
||||
DEVICE_TYPE_VE_BUS = 0x0C,
|
||||
DEVICE_TYPE_DC_ENERGY_METER = 0x0D,
|
||||
DEVICE_TYPE_ORION_XS = 0x0F
|
||||
};
|
||||
|
||||
// --- Device state for Solar Charger ---
|
||||
@@ -72,27 +75,17 @@ struct victronManufacturerData {
|
||||
struct victronSolarChargerPayload {
|
||||
uint8_t deviceState;
|
||||
uint8_t errorCode;
|
||||
int16_t batteryVoltage; // 10mV units
|
||||
int16_t batteryCurrent; // 10mA units (signed)
|
||||
uint16_t yieldToday; // 10Wh units
|
||||
int16_t batteryVoltage; // 0.01V units (signed)
|
||||
int16_t batteryCurrent; // 0.1A units (signed)
|
||||
uint16_t yieldToday; // 0.01kWh (10Wh) units
|
||||
uint16_t inputPower; // 1W units
|
||||
uint16_t loadCurrent; // 10mA units (0xFFFF = no load)
|
||||
uint16_t loadCurrent; // 9-bit field, 0.1A units (0x1FF = no load)
|
||||
uint8_t reserved[2];
|
||||
} __attribute__((packed));
|
||||
|
||||
struct victronBatteryMonitorPayload {
|
||||
uint16_t remainingMins;
|
||||
uint16_t batteryVoltage; // 10mV units
|
||||
uint8_t alarms;
|
||||
uint16_t auxData; // 10mV (voltage) or 0.01K (temperature)
|
||||
uint8_t currentLow;
|
||||
uint8_t currentMid;
|
||||
uint8_t currentHigh_consumedLow; // Current bits 16-21 (low 6), consumed bits 0-1 (high 2)
|
||||
uint8_t consumedMid;
|
||||
uint8_t consumedHigh;
|
||||
uint16_t soc; // 0.1% units (10-bit)
|
||||
uint8_t reserved[2];
|
||||
} __attribute__((packed));
|
||||
// NOTE: The battery monitor payload is bit-packed (16-bit alarm, 2-bit aux mode,
|
||||
// 22-bit current, 20-bit consumed Ah, 10-bit SOC) and does NOT byte-align, so it
|
||||
// is decoded by bit offset directly in parseBatteryMonitor() rather than a struct.
|
||||
|
||||
struct victronInverterPayload {
|
||||
uint8_t deviceState;
|
||||
@@ -129,6 +122,19 @@ struct VictronSolarData {
|
||||
float loadCurrent; // A
|
||||
};
|
||||
|
||||
struct VictronACChargerData {
|
||||
uint8_t chargeState; // SolarChargerState enum (shared charger states)
|
||||
uint8_t errorCode;
|
||||
float voltage1; // V (output 1)
|
||||
float current1; // A (output 1)
|
||||
float voltage2; // V (output 2, 0 if absent)
|
||||
float current2; // A (output 2, 0 if absent)
|
||||
float voltage3; // V (output 3, 0 if absent)
|
||||
float current3; // A (output 3, 0 if absent)
|
||||
float temperature; // C (0 if not available)
|
||||
float acCurrent; // A (0 if not available)
|
||||
};
|
||||
|
||||
struct VictronBatteryData {
|
||||
float voltage; // V
|
||||
float current; // A
|
||||
@@ -179,6 +185,7 @@ struct VictronDevice {
|
||||
VictronBatteryData battery;
|
||||
VictronInverterData inverter;
|
||||
VictronDCDCData dcdc;
|
||||
VictronACChargerData acCharger;
|
||||
};
|
||||
};
|
||||
|
||||
@@ -236,6 +243,7 @@ private:
|
||||
void processDevice(BLEAdvertisedDevice& dev);
|
||||
bool parseAdvertisement(DeviceEntry* entry, const victronManufacturerData& mfg);
|
||||
bool parseSolarCharger(const uint8_t* data, size_t len, VictronSolarData& result);
|
||||
bool parseACCharger(const uint8_t* data, size_t len, VictronACChargerData& result);
|
||||
bool parseBatteryMonitor(const uint8_t* data, size_t len, VictronBatteryData& result);
|
||||
bool parseInverter(const uint8_t* data, size_t len, VictronInverterData& result);
|
||||
bool parseDCDCConverter(const uint8_t* data, size_t len, VictronDCDCData& result);
|
||||
|
||||