87 lines
2.6 KiB
Plaintext
87 lines
2.6 KiB
Plaintext
# SPDX-License-Identifier: MIT
|
|
# Copyright (c) 2026 Scott Penrose <scottp@dd.com.au>
|
|
|
|
menuconfig RB9704
|
|
bool "RockBLOCK 9704 Iridium modem"
|
|
default y
|
|
depends on DT_HAS_ROCK7_ROCKBLOCK_9704_ENABLED
|
|
depends on SERIAL
|
|
select RING_BUFFER if RB9704_ZEPHYR_BEFORE_4_5
|
|
select UART_INTERRUPT_DRIVEN
|
|
help
|
|
Ground Control's RockBLOCK 9704 (Iridium Certus, IMT messages) on the
|
|
UART its devicetree node sits on. Builds Ground Control's library,
|
|
pinned pristine at modules/lib/rockblock9704, with a Zephyr serial
|
|
port and one worker thread that owns it. <rb9704/rb9704.h> is the API.
|
|
|
|
if RB9704
|
|
|
|
# Zephyr 4.5 made the ring buffer header-only, and CONFIG_RING_BUFFER there
|
|
# brings back the deprecated legacy implementation. Before 4.5 it is what
|
|
# builds the ring buffer at all. KERNELVERSION is 0xMMmmpp00.
|
|
config RB9704_KERNEL_VERSION
|
|
hex
|
|
default "$(KERNELVERSION)"
|
|
|
|
config RB9704_ZEPHYR_BEFORE_4_5
|
|
def_bool RB9704_KERNEL_VERSION < 0x4050000
|
|
|
|
config RB9704_MESSAGE_MAX
|
|
int "Largest message in either direction (bytes)"
|
|
default 2048
|
|
range 16 100000
|
|
help
|
|
The modem takes up to 100 kB, and the library keeps one static buffer
|
|
of this size for messages out and one for messages in, plus one in
|
|
this module for the copy rb9704_send takes. 2 kB is three buffers of
|
|
2 kB; raise it as far as the RAM allows.
|
|
|
|
DT_COMPAT_ROCK7_ROCKBLOCK_9704 := rock7,rockblock-9704
|
|
|
|
config RB9704_POWER
|
|
bool "Drive the power pins from devicetree"
|
|
default y if $(dt_compat_any_has_prop,$(DT_COMPAT_ROCK7_ROCKBLOCK_9704),iridium-enable-gpios)
|
|
select GPIO
|
|
help
|
|
I_EN, I_BTD and P_EN as the devicetree node gives them, in Ground
|
|
Control's start-up and shutdown sequence. I_EN is the one that
|
|
switches the modem; without it the modem is taken to be powered, as
|
|
the board is with the pins left open.
|
|
|
|
config RB9704_WORKER_STACK_SIZE
|
|
int "Worker thread stack size"
|
|
default 8192
|
|
help
|
|
Measured, not guessed: the library parks a 1.5 kB MT segment on the
|
|
stack in rbPoll(), with cJSON's recursion beneath it. A smaller stack
|
|
overflows only when a message arrives, which may be days after the
|
|
change.
|
|
|
|
config RB9704_WORKER_PRIORITY
|
|
int "Worker thread priority"
|
|
default 8
|
|
|
|
config RB9704_RX_RING_SIZE
|
|
int "Serial receive ring (bytes)"
|
|
default 8192
|
|
help
|
|
The library's longest JSPR line is 8 kB.
|
|
|
|
config RB9704_SHELL
|
|
bool "`rb9704` shell command"
|
|
default y
|
|
depends on SHELL
|
|
|
|
config RB9704_UPSTREAM_DIR
|
|
string "Where Ground Control's library is"
|
|
default ""
|
|
help
|
|
Empty: <west topdir>/modules/lib/rockblock9704, where this
|
|
repository's west.yml puts it.
|
|
|
|
module = RB9704
|
|
module-str = rb9704
|
|
source "subsys/logging/Kconfig.template.log_config"
|
|
|
|
endif # RB9704
|